Bugs: hrc_process_events


Caveats

  1. Aspect files must be arranged in chronological order

Bugs

  1. Degap filename length (16 May 2007)

  2. Failure with level 2 event file (16 May 2007)


Caveats

  1. Aspect files must be arranged in chronological order

    hrc_process_events assumes that the aspect files given in the acaofffile and alignmentfile parameters are arranged in chronological order. If the files are not in order, the tool will exit with an error.

    If you have not altered the original filenames, a simple "ls" will put them in order, as the time is listed in the filename:

    unix% pwd
    /data/459/primary
    
    unix% ls -1 pcad*
    pcadf063874624N002_asol1.fits
    pcadf063875522N002_asol1.fits
    pcadf063902942N002_asol1.fits
    

    Otherwise, get the value from the TSTART header keyword:

    unix% dmkeypar pcad_1.fits TSTART echo+
    63875522.3455031
    

    and put the files in chronological order.


Bugs

  1. Degap filename length (16 May 2007)

    There is a 127 character limit to the filename length (including path) of the HRC degap file. If the filename is > 127 characters, then random memory can get over-written.

  2. Failure with level 2 event file (16 May 2007)

    The tool fails if you give it a level 2 file as input, rather than printing an error message. The level 2 file is missing a number of columns required by hrc_process_events.