About Chandra Archive Proposer Instruments & Calibration Newsletters Data Analysis HelpDesk Calibration Database NASA Archives & Centers Chandra Science Links

Skip the navigation links
Last modified: 21 November 2006

URL: http://cxc.harvard.edu/ciao3.4/bugs/acisreadcorr.html
Hardcopy (PDF): A4 | Letter

Bugs: acisreadcorr


Bugs

  1. There is a bug in acisreadcorr such that it does not work correctly on observations that used a subarray.

  2. Interleaved mode data: incorrect EXPTIME value in the streak events


Bugs

  1. There is a bug in acisreadcorr such that it does not work correctly on observations that used a subarray.

    Please refer to the "Remove the ACIS readout streak" thread for full details.

  2. Interleaved mode data: incorrect EXPTIME value in the streak events

    The following bug applies only to interleaved mode data:

    The computation of the TIME of the events in the streak is correct with the exception of the value of EXPTIME.

    In one example of this bug, a value of 3.3 s was used instead of the correct value of 0.3 s. The exposure time of the secondary frames of obsid 107 is 3.3 s, but this run of acisreadcorr used the data from the primary frames (0.3 s exposure time).

Hardcopy (PDF): A4 | Letter
Last modified: 21 November 2006


The Chandra X-Ray Center (CXC) is operated for NASA by the Smithsonian Astrophysical Observatory.
60 Garden Street, Cambridge, MA 02138 USA.    Email: cxcweb@head.cfa.harvard.edu
Smithsonian Institution, Copyright © 1998-2004. All rights reserved.