| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| agrndadc | -1.578e-04 | 1.981e-06 | (4.60+/-36.28)e-5 | (3.13+/-7.23)e-5 | V | Analog fround A/D convert reading | No Violation Check | |
| fatabadc | -0.001 | 1.824e-05 | 5.00 +/- 0.00 | (5.70+/-3.50)e-4 | V | FA Tab Position Sensor A/D Converter | No Violation Check | |
| n15vadc | -5.521e-04 | 0.003 | -15.01 +/- 0.36 | (5.88+/-15.63)e-5 | V | -15V Power Supply A/D Converter Reading | No Violation Check | |
| p15vadc | -5.703e-04 | 5.174e-06 | 14.96 +/- 0.00 | -(3.92+/-2.69)e-4 | V | +15V Power Supply A/D Converter Reading | No Violation Check | |
| p5vadc | -0.013 | 1.792e-04 | 4.97 +/- 0.03 | 0.01 +/- 0.00 | V | +5V Power Supply A/D Converter Reading | No Violation Check | |
| tsctabadc | -0.002 | 3.358e-05 | 5.00 +/- 0.01 | (7.74+/-5.73)e-4 | V | TSC Tab Position Sensor A/D converter | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 11, 2026
Last Site Modification: Sep 30, 2021