| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| eb1ci | off | -1.791e-05 | 6.758e-06 | 0.33 +/- 0.18 | -(1.59+/-8.60)e-4 | AMP | BATT 1 CHARGE CURRENT | No Violation Check | on | 2.643e-04 | 3.187e-04 | 0.53 +/- 0.58 | (0.00+/-0.00)e0 | No Violation Check |
| eb1di | off | -6.909e-05 | 2.635e-05 | 0.07 +/- 0.69 | -(1.77+/-24.99)e-4 | AMP | BATT 1 DISCHARGE CURRENT | No Violation Check | on | 1.556e-04 | 0.001 | 0.82 +/- 2.65 | (0.00+/-0.00)e0 | No Violation Check |
| eb1v | off | 7.915e-05 | 4.021e-06 | 32.36 +/- 0.11 | -(3.83+/-3.22)e-4 | V | BATT 1 VOLTAGE | No Violation Check | on | -4.510e-04 | 1.643e-04 | 32.19 +/- 0.32 | (0.00+/-0.00)e0 | No Violation Check |
| eb2ci | off | -1.242e-05 | 6.483e-06 | 0.28 +/- 0.17 | -(1.93+/-8.28)e-4 | AMP | BATT 2 CHARGE CURRENT | No Violation Check | on | 2.714e-04 | 3.069e-04 | 0.48 +/- 0.56 | (0.00+/-0.00)e0 | No Violation Check |
| eb2di | off | -6.940e-05 | 2.658e-05 | 0.06 +/- 0.69 | (7.30+/-24.78)e-4 | AMP | BATT 2 DISCHARGE CURRENT | No Violation Check | on | 6.100e-05 | 0.001 | 0.76 +/- 2.60 | (0.00+/-0.00)e0 | No Violation Check |
| eb2v | off | 1.830e-05 | 3.249e-06 | 32.30 +/- 0.09 | -(5.27+/-17.10)e-5 | V | BATT 2 VOLTAGE | No Violation Check | on | -2.283e-04 | 1.458e-04 | 32.12 +/- 0.27 | (0.00+/-0.00)e0 | No Violation Check |
| eb3ci | off | -7.181e-06 | 4.911e-06 | 0.27 +/- 0.13 | -(4.30+/-6.70)e-4 | AMP | BATT 3 CHARGE CURRENT | No Violation Check | on | 1.884e-04 | 2.146e-04 | 0.41 +/- 0.39 | (0.00+/-0.00)e0 | No Violation Check |
| eb3di | off | -7.011e-05 | 2.675e-05 | 0.06 +/- 0.70 | (2.28+/-24.60)e-4 | AMP | BATT 3 DISCHARGE CURRENT | No Violation Check | on | 1.054e-04 | 0.001 | 0.76 +/- 2.63 | (0.00+/-0.00)e0 | No Violation Check |
| eb3v | off | 3.479e-05 | 3.687e-06 | 32.02 +/- 0.10 | (1.86+/-2.62)e-4 | V | BATT 3 VOLTAGE | No Violation Check | on | -2.938e-04 | 1.709e-04 | 31.83 +/- 0.32 | (0.00+/-0.00)e0 | No Violation Check |
| ecnv1v | -1.584e-06 | 6.610e-07 | 15.03 +/- 0.02 | -(1.33+/-9.15)e-5 | V | CONV 1 +15V OUTPUT | No Violation Check | |
| ecnv2v | -1.743e-06 | 5.657e-07 | 14.96 +/- 0.01 | -(3.60+/-6.61)e-5 | V | CONV 2 +15V OUTPUT | No Violation Check | |
| ecnv3v | -5.680e-07 | 2.217e-07 | 15.39 +/- 0.01 | -(2.93+/-2.23)e-5 | V | CONV 3 +15V OUTPUT | No Violation Check | |
| eepa5v | 7.321e-07 | 7.303e-07 | 5.25 +/- 0.02 | (8.51+/-8.49)e-5 | V | +5V RCTU_EP A | No Violation Check | |
| eepb5v | 1.669e-07 | 3.548e-07 | 0.04 +/- 0.01 | (3.21+/-4.40)e-5 | V | +5V RCTU_EP B | No Violation Check | |
| eochrgb1 | -1.718e-07 | 1.589e-07 | 1.00 +/- 0.00 | -(2.13+/-79.75)e-7 | na | BATT 1 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb2 | -1.902e-07 | 1.557e-07 | 1.00 +/- 0.00 | -(2.45+/-7.62)e-6 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb3 | -2.102e-07 | 1.818e-07 | 1.00 +/- 0.01 | -(3.27+/-10.66)e-6 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eoesac1c | 6.044e-05 | 1.180e-04 | 11.77 +/- 1.16 | (2.14+/-20.47)e-4 | na | -Y SOLAR ARRAY CURRENT - COUNTS (ESAMYI) | No Violation Check | |
| eoesac2c | 6.354e-05 | 1.119e-04 | 11.38 +/- 1.10 | -(7.16+/-19.38)e-4 | na | +Y SOLAR ARRAY CURRENT - COUNTS (ESAPYI) | No Violation Check | |
| eoeb1dic | -1.297e-04 | 4.486e-05 | 0.04 +/- 0.44 | -(8.11+/-29.01)e-5 | AMP | TTERY 1 DISCHARGE CURRENT - COUNTS (EB1DI) | No Violation Check | |
| eoeb1vc | 7.126e-05 | 1.694e-05 | 32.54 +/- 0.17 | -(8.52+/-26.01)e-5 | na | BATTERY 1 VOLTAGE - COUNTS | No Violation Check | |
| eoeb2cic | 9.859e-06 | 8.516e-06 | 0.26 +/- 0.08 | -(1.46+/-0.69)e-4 | na | BATTERY 2 CHARGE CURRENT - COUNTS ( EB2CI) | No Violation Check | |
| eoeb2vc | 1.009e-04 | 1.498e-05 | 32.26 +/- 0.15 | -(2.57+/-2.29)e-4 | na | VOLTAGE - COUNTS | No Violation Check | |
| eoeb3cic | 1.328e-05 | 7.665e-06 | 0.26 +/- 0.07 | -(9.50+/-8.48)e-5 | na | BATTERY 3 CHARGE CURRENT - COUNTS ( EB3CI) | No Violation Check | |
| eoeb3vc | 3.497e-05 | 1.454e-05 | 32.17 +/- 0.14 | -(4.40+/-2.30)e-4 | na | BATTERY 3 VOLTAGE - COUNTS | No Violation Check | |
| eoecnv1c | 6.425e-07 | 4.537e-06 | 14.97 +/- 0.04 | -(1.17+/-0.81)e-4 | na | PCU CONVERTER 1: +15V OUTPUT - ANALOG (ECNV1V) | No Violation Check | |
| eoecnv2c | -8.196e-06 | 4.336e-06 | 14.93 +/- 0.04 | (1.05+/-0.73)e-4 | na | PCU CONVERTER 2: +15V OUTPUT - ANALOG (ECNV2V) | No Violation Check | |
| eoecnv3c | 5.945e-06 | 4.225e-06 | 15.36 +/- 0.04 | (1.26+/-0.67)e-4 | na | PCU CONVERTER 3: +15V OUTPUT - ANALOG (ECNV3V) | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 10, 2026
Last Site Modification: Sep 30, 2021