Back to Top

HRCTEMP
Static Version: Max --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -4.3040.061(2.87+/-0.10)e2-0.07 +/- 0.89KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.2970.028(2.98+/-0.03)e2-0.35 +/- 1.04KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -4.4590.066(2.80+/-0.11)e2-0.78 +/- 0.99KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -3.8410.053(2.81+/-0.09)e2-0.53 +/- 0.71KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -4.5660.059(2.80+/-0.10)e2-0.29 +/- 0.70KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -5.7310.088(2.78+/-0.14)e2-1.27 +/- 1.48KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -5.2240.081(2.75+/-0.13)e2-1.38 +/- 1.47KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -2.1110.037(2.89+/-0.05)e20.82 +/- 0.97KPMT 1 TEMPERATURENo Violation Check
2pmt2t -2.5760.042(2.90+/-0.07)e20.52 +/- 1.03KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -2.6550.042(2.81+/-0.07)e20.44 +/- 0.81KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: May 09, 2026
Last Site Modification: Sep 30, 2021