| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| eb1ci | off | -1.985e-05 | 4.972e-06 | 0.32 +/- 0.12 | (2.96+/-47.61)e-5 | AMP | BATT 1 CHARGE CURRENT | No Violation Check | on | 2.592e-04 | 1.880e-04 | 0.38 +/- 0.35 | (0.00+/-0.00)e0 | No Violation Check |
| eb1di | off | -3.011e-05 | 9.656e-06 | 0.03 +/- 0.23 | (4.41+/-76.39)e-5 | AMP | BATT 1 DISCHARGE CURRENT | No Violation Check | on | 1.741e-04 | 6.728e-04 | 0.32 +/- 1.23 | (0.00+/-0.00)e0 | No Violation Check |
| eb1v | off | 4.415e-05 | 6.449e-06 | 32.31 +/- 0.15 | -(1.24+/-5.19)e-4 | V | BATT 1 VOLTAGE | No Violation Check | on | -4.859e-04 | 3.484e-04 | 32.01 +/- 0.65 | (0.00+/-0.00)e0 | No Violation Check |
| eb2ci | off | -1.408e-05 | 4.767e-06 | 0.27 +/- 0.11 | (1.13+/-4.54)e-4 | AMP | BATT 2 CHARGE CURRENT | No Violation Check | on | 2.831e-04 | 1.808e-04 | 0.33 +/- 0.34 | (0.00+/-0.00)e0 | No Violation Check |
| eb2di | off | -2.966e-05 | 9.547e-06 | 0.02 +/- 0.23 | (4.45+/-75.10)e-5 | AMP | BATT 2 DISCHARGE CURRENT | No Violation Check | on | 1.771e-04 | 6.636e-04 | 0.30 +/- 1.21 | (0.00+/-0.00)e0 | No Violation Check |
| eb2v | off | 1.065e-04 | 6.314e-06 | 32.26 +/- 0.15 | -(7.25+/-5.58)e-4 | V | BATT 2 VOLTAGE | No Violation Check | on | -4.372e-04 | 3.308e-04 | 32.00 +/- 0.61 | (0.00+/-0.00)e0 | No Violation Check |
| eb3ci | off | -1.737e-05 | 3.959e-06 | 0.26 +/- 0.10 | (2.30+/-4.12)e-4 | AMP | BATT 3 CHARGE CURRENT | No Violation Check | on | 1.757e-04 | 1.274e-04 | 0.30 +/- 0.24 | (0.00+/-0.00)e0 | No Violation Check |
| eb3di | off | -2.941e-05 | 9.483e-06 | 0.02 +/- 0.23 | (4.19+/-74.32)e-5 | AMP | BATT 3 DISCHARGE CURRENT | No Violation Check | on | 1.706e-04 | 6.621e-04 | 0.30 +/- 1.21 | (0.00+/-0.00)e0 | No Violation Check |
| eb3v | off | 1.028e-04 | 6.485e-06 | 31.96 +/- 0.16 | -0.00 +/- 0.00 | V | BATT 3 VOLTAGE | No Violation Check | on | -4.805e-04 | 3.395e-04 | 31.71 +/- 0.63 | (0.00+/-0.00)e0 | No Violation Check |
| ecnv1v | -1.424e-06 | 4.080e-07 | 14.89 +/- 0.01 | (5.02+/-5.07)e-5 | V | CONV 1 +15V OUTPUT | No Violation Check | |
| ecnv2v | -3.529e-06 | 3.987e-07 | 14.84 +/- 0.01 | (2.69+/-1.04)e-4 | V | CONV 2 +15V OUTPUT | No Violation Check | |
| ecnv3v | 3.932e-06 | 2.630e-07 | 15.27 +/- 0.01 | (4.58+/-3.05)e-5 | V | CONV 3 +15V OUTPUT | No Violation Check | |
| eepa5v | 1.528e-09 | 4.419e-09 | 5.24 +/- 0.00 | (8.79+/-0.65)e-13 | V | +5V RCTU_EP A | No Violation Check | |
| eepb5v | 1.408e-07 | 9.654e-08 | 0.04 +/- 0.00 | (1.09+/-1.20)e-5 | V | +5V RCTU_EP B | No Violation Check | |
| eochrgb1 | 4.120e-07 | 2.630e-07 | 1.00 +/- 0.01 | -(2.52+/-21.01)e-6 | na | BATT 1 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb2 | 3.566e-07 | 2.466e-07 | 1.00 +/- 0.01 | -(2.79+/-19.24)e-6 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb3 | 4.135e-07 | 2.696e-07 | 1.00 +/- 0.01 | -(1.32+/-227.40)e-7 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eoesac1c | 1.756e-04 | 1.191e-04 | 11.01 +/- 1.07 | 0.00 +/- 0.00 | na | -Y SOLAR ARRAY CURRENT - COUNTS (ESAMYI) | No Violation Check | |
| eoesac2c | 1.591e-04 | 1.139e-04 | 10.66 +/- 1.02 | 0.00 +/- 0.00 | na | +Y SOLAR ARRAY CURRENT - COUNTS (ESAPYI) | No Violation Check | |
| eoeb1dic | -1.518e-04 | 4.268e-05 | 0.03 +/- 0.39 | -(1.53+/-27.81)e-5 | AMP | TTERY 1 DISCHARGE CURRENT - COUNTS (EB1DI) | No Violation Check | |
| eoeb1vc | 1.403e-04 | 2.307e-05 | 32.28 +/- 0.21 | -(5.03+/-3.44)e-4 | na | BATTERY 1 VOLTAGE - COUNTS | No Violation Check | |
| eoeb2cic | 3.329e-06 | 9.352e-06 | 0.27 +/- 0.08 | -(2.45+/-7.69)e-5 | na | BATTERY 2 CHARGE CURRENT - COUNTS ( EB2CI) | No Violation Check | |
| eoeb2vc | 1.621e-04 | 2.188e-05 | 32.23 +/- 0.20 | -(7.46+/-3.24)e-4 | na | VOLTAGE - COUNTS | No Violation Check | |
| eoeb3cic | 2.843e-06 | 8.469e-06 | 0.26 +/- 0.08 | -(5.75+/-9.32)e-5 | na | BATTERY 3 CHARGE CURRENT - COUNTS ( EB3CI) | No Violation Check | |
| eoeb3vc | 1.128e-04 | 2.177e-05 | 32.16 +/- 0.20 | (4.84+/-3.21)e-4 | na | BATTERY 3 VOLTAGE - COUNTS | No Violation Check | |
| eoecnv1c | -1.267e-06 | 1.815e-06 | 14.89 +/- 0.02 | (8.78+/-3.20)e-5 | na | PCU CONVERTER 1: +15V OUTPUT - ANALOG (ECNV1V) | No Violation Check | |
| eoecnv2c | -7.323e-06 | 1.991e-06 | 14.83 +/- 0.02 | (6.91+/-4.21)e-5 | na | PCU CONVERTER 2: +15V OUTPUT - ANALOG (ECNV2V) | No Violation Check | |
| eoecnv3c | 2.694e-06 | 2.009e-06 | 15.26 +/- 0.02 | -(4.45+/-2.97)e-5 | na | PCU CONVERTER 3: +15V OUTPUT - ANALOG (ECNV3V) | No Violation Check |