| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -2.110e-04 | 8.928e-05 | (2.12+/-0.02)e2 | -0.05 +/- 0.03 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -2.353e-04 | 8.851e-05 | (2.13+/-0.02)e2 | -0.06 +/- 0.03 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 3.375e-04 | 1.555e-04 | (1.52+/-0.04)e2 | -0.02 +/- 0.04 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.057 | 0.003 | (6.54+/-0.78)e2 | -0.98 +/- 0.57 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.001 | 1.607e-04 | (2.62+/-0.04)e2 | -0.05 +/- 0.07 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 9.313e-04 | 2.536e-04 | (2.88+/-0.07)e2 | -0.06 +/- 0.06 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.001 | 2.616e-04 | (2.88+/-0.07)e2 | -0.03 +/- 0.06 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.001 | 2.536e-04 | (2.91+/-0.07)e2 | -0.05 +/- 0.06 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -7.374e-04 | 1.140e-04 | (2.49+/-0.03)e2 | -0.04 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -6.721e-04 | 1.054e-04 | (2.45+/-0.03)e2 | -0.06 +/- 0.04 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -6.618e-04 | 2.264e-04 | (3.02+/-0.06)e2 | 0.04 +/- 0.07 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -5.520e-04 | 2.205e-04 | (2.93+/-0.06)e2 | 0.06 +/- 0.07 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.001 | 1.712e-04 | (3.44+/-0.05)e2 | 0.00 +/- 0.03 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -7.479e-05 | 8.832e-05 | (1.94+/-0.02)e2 | -0.04 +/- 0.03 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -6.939e-05 | 8.948e-05 | (1.94+/-0.02)e2 | -0.05 +/- 0.03 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jul 06, 2026
Last Site Modification: Sep 30, 2021