| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.563 | 0.020 | (2.09+/-0.03)e2 | -1.37 +/- 0.99 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.576 | 0.020 | (2.10+/-0.03)e2 | -0.94 +/- 0.99 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.440 | 0.024 | (1.48+/-0.03)e2 | -0.20 +/- 1.08 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 92.774 | 1.373 | (3.53+/-2.45)e2 | 11.04 +/- 26.87 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.538 | 0.034 | (2.57+/-0.04)e2 | -1.25 +/- 1.45 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.061 | 0.044 | (2.83+/-0.05)e2 | -0.14 +/- 1.63 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.061 | 0.047 | (2.83+/-0.06)e2 | -0.28 +/- 1.86 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.058 | 0.043 | (2.86+/-0.05)e2 | -0.47 +/- 1.68 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.552 | 0.023 | (2.42+/-0.03)e2 | -1.05 +/- 1.11 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.053 | 0.047 | (2.97+/-0.06)e2 | 1.89 +/- 2.05 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.082 | 0.045 | (2.88+/-0.05)e2 | 2.78 +/- 2.01 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 1.968 | 0.097 | (3.39+/-0.12)e2 | 3.08 +/- 3.63 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.475 | 0.019 | (1.92+/-0.02)e2 | -1.06 +/- 0.90 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.504 | 0.019 | (1.91+/-0.02)e2 | -0.64 +/- 0.90 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 28, 2026