| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.644 | 0.022 | (2.09+/-0.03)e2 | 0.19 +/- 1.01 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.664 | 0.022 | (2.10+/-0.03)e2 | 0.17 +/- 0.99 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.511 | 0.027 | (1.48+/-0.03)e2 | 1.05 +/- 1.04 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 111.283 | 1.372 | (3.48+/-2.51)e2 | 21.98 +/- 21.52 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.571 | 0.037 | (2.57+/-0.04)e2 | -0.01 +/- 1.41 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.017 | 0.049 | (2.83+/-0.05)e2 | 1.03 +/- 1.68 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.011 | 0.053 | (2.83+/-0.06)e2 | 1.68 +/- 1.88 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.001 | 0.049 | (2.86+/-0.05)e2 | 0.66 +/- 1.70 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.621 | 0.025 | (2.42+/-0.03)e2 | 0.36 +/- 1.09 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.019 | 0.052 | (2.97+/-0.06)e2 | -0.43 +/- 2.03 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.164 | 0.050 | (2.88+/-0.05)e2 | 1.05 +/- 1.98 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.248 | 0.110 | (3.39+/-0.12)e2 | 0.39 +/- 3.88 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.554 | 0.021 | (1.92+/-0.02)e2 | 0.23 +/- 0.90 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.586 | 0.021 | (1.91+/-0.02)e2 | 0.43 +/- 0.91 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: May 08, 2026
Last Site Modification: Sep 30, 2021