| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.073 | 0.015 | (2.12+/-0.01)e2 | 37.65 +/- 90.97 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.102 | 0.014 | (2.13+/-0.01)e2 | -20.88 +/- 79.02 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.075 | 0.034 | (1.53+/-0.03)e2 | (1.14+/-1.95)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 7.641 | 0.931 | (4.78+/-0.88)e2 | -(3.62+/-4.92)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.084 | 0.036 | (2.63+/-0.03)e2 | -(1.65+/-1.01)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.115 | 0.066 | (2.90+/-0.06)e2 | (5.65+/-4.40)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.230 | 0.068 | (2.89+/-0.06)e2 | (4.39+/-4.44)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.189 | 0.067 | (2.92+/-0.06)e2 | (3.29+/-4.37)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.082 | 0.023 | (2.49+/-0.02)e2 | -(1.83+/-0.68)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.058 | 0.021 | (2.45+/-0.02)e2 | -53.57 +/- 57.85 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.079 | 0.051 | (3.05+/-0.05)e2 | -20.87 +/- 196.87 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.082 | 0.050 | (2.97+/-0.05)e2 | -30.86 +/- 193.61 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 5.174e-10 | 1.014e-06 | (3.45+/-0.00)e2 | (2.07+/-1.87)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.040 | 0.016 | (1.94+/-0.02)e2 | 22.78 +/- 112.59 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.043 | 0.016 | (1.94+/-0.02)e2 | (1.01+/-1.17)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Sep 14, 2026
Last Site Modification: Sep 30, 2021