| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 4.075e-04 | 9.373e-05 | (2.12+/-0.02)e2 | -0.01 +/- 0.03 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 3.677e-04 | 9.279e-05 | (2.13+/-0.02)e2 | 0.01 +/- 0.03 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 5.718e-04 | 1.762e-04 | (1.55+/-0.04)e2 | 0.03 +/- 0.05 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.065 | 0.004 | (6.34+/-1.06)e2 | -0.06 +/- 0.76 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -3.734e-04 | 1.636e-04 | (2.64+/-0.04)e2 | -0.06 +/- 0.07 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.002 | 2.767e-04 | (2.91+/-0.07)e2 | -0.04 +/- 0.06 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.002 | 2.838e-04 | (2.91+/-0.07)e2 | 0.01 +/- 0.06 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.003 | 2.782e-04 | (2.94+/-0.07)e2 | -0.00 +/- 0.06 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -5.987e-05 | 1.174e-04 | (2.50+/-0.03)e2 | -0.03 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 1.863e-05 | 1.109e-04 | (2.46+/-0.03)e2 | -0.01 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 9.619e-04 | 2.431e-04 | (3.06+/-0.06)e2 | -0.03 +/- 0.08 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.001 | 2.381e-04 | (3.00+/-0.06)e2 | -0.04 +/- 0.08 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 5.558e-04 | 1.204e-04 | (3.45+/-0.03)e2 | 0.01 +/- 0.01 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 4.243e-04 | 9.491e-05 | (1.95+/-0.02)e2 | 0.02 +/- 0.03 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 4.267e-04 | 9.586e-05 | (1.95+/-0.02)e2 | 0.01 +/- 0.03 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Sep 13, 2026
Last Site Modification: Sep 30, 2021