| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.476 | 0.020 | (2.13+/-0.03)e2 | -1.07 +/- 1.03 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.511 | 0.020 | (2.13+/-0.03)e2 | -1.03 +/- 1.05 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.872 | 0.067 | (1.59+/-0.08)e2 | -0.32 +/- 2.21 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 110.612 | 1.145 | (3.92+/-2.57)e2 | 25.57 +/- 7.56 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.748 | 0.027 | (2.64+/-0.03)e2 | -2.27 +/- 1.35 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.101 | 0.055 | (2.99+/-0.06)e2 | -1.47 +/- 2.30 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.110 | 0.054 | (2.99+/-0.06)e2 | -0.69 +/- 2.23 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.137 | 0.054 | (3.02+/-0.06)e2 | 0.07 +/- 2.26 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.130 | 0.024 | (2.49+/-0.02)e2 | 0.13 +/- 0.87 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.596 | 0.021 | (2.46+/-0.03)e2 | -2.31 +/- 1.07 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.350 | 0.057 | (3.09+/-0.07)e2 | -1.42 +/- 2.56 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.240 | 0.055 | (3.03+/-0.07)e2 | -0.82 +/- 2.47 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.119 | 0.020 | (3.45+/-0.02)e2 | 0.00 +/- 0.01 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.437 | 0.028 | (1.96+/-0.03)e2 | 0.04 +/- 1.14 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.480 | 0.028 | (1.96+/-0.03)e2 | -0.26 +/- 1.14 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 27, 2026