File $Source: /home/juda/www/hrc_flight/RCS/rad_hi.html,v $
Version $Revision: 1.6 $
Last Update $Date: 1999/05/10 18:08:08 $
HRC CCB Status Approved

OP03 Procedures op03:

HRC Command Sequences

Radiation High Commands - SCS #85

Description:

This command sequence should be used in response to signals from the AXAF radiation monitor (EPHIN) that indicate the observatory is in a high-flux particle radiation environment. The goal is to protect the parts of the HRC instrument that may be degraded by continued operation in this environment (see HRC CARD item HRC-R-002. This command sequence turns off all of the HRC HV power supplies and sets the requested step levels to 0. It then disables the HRC-I and -S MCP HV turn on SCSs so that they cannot be executed. Once this sequence has run it is only possible to get the HRC back to operating on the nominal science mission via a ground contact with the observatory.

This command sequence is based on the HRC EGSE scripts allhvoff.cmd

Cautions/Restrictions:

None

Delta-Time Command Mnemonic Description Cmd Field Mnemonic Data Parameter Telemetry Verifier Expected Value Notes
00:00:01.000 2SPHVOF HRC-S HVPS Off     2SPONST OFF sd0100
00:00:01.000 2IMHVOF HRC-I HVPS Off     2IMONST OFF sd0900
00:00:01.000 2S1HVOF Shield PMT#1 HVPS off     2S1ONST OFF sd0500
00:00:01.000 2S2HVOF Shield PMT#2 HVPS off     2S2ONST OFF sd0d00
00:00:01.000 2SPTTHV Set HRC-S top MCP HV step to 0 2SPTTHV2 0 2SPTPAST 0 sd0200
00:00:01.000 2SPTBHV Set HRC-S bottom MCP HV step to 0 2SPTBHV2 0 2SPBPAST 0 sd0300
00:00:01.000 2IMTTHV Set HRC-I top MCP HV step to 0 2IMTTHV2 0 2IMTPAST 0 sd0a00
00:00:01.000 2IMTBHV Set HRC-I bottom MCP HV step to 0 2IMTBHV2 0 2IMBPAST 0 sd0b00
00:00:01.000 2S1STHV Set shield PMT#1 HV step 2S1STHV2 0 2S1HVST 0 sd0600
00:00:01.000 2S2STHV Set shield PMT#2 HV step to 0 2S2STHV2 0 2S2HVST 0 sd0e00
00:00:00.064 CODISASX Disable SCS#92 - HRC-I MCP HV On CODISAS1 92      
00:00:00.064 CODISASX Disable SCS#93 - HRC-S MCP HV On CODISAS1 93      


$Log: rad_hi.html,v $

Revision 1.6 1999/05/10 18:08:08 jhc

corrected initial time delay to 1 sec

Revision 1.5 1998/05/18 15:54:34 juda

corrected telemetry verifier mnemonics for MCP HV Step commands (2IMTPST -> 2IMTPAST, 2IMBPST -> 2IMBPAST, 2SPTPST -> 2SPTPAST and 2SPBPST -> 2SPBPAST)

Revision 1.4 1998/05/12 20:08:09 juda

Updated the SCS # that are disabled to the HRC-I and -S MCP HV On SCSs

Revision 1.3 1998/05/06 20:08:15 juda

*** empty log message ***

Revision 1.2 1998/05/06 19:47:00 juda

Added OBC SCS # - marked as approved

Revision 1.1 1998/05/05 13:06:28 juda

Initial revision


Dr. Michael Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356
E-mail: mjuda@cfa.harvard.edu