File | $Source: /home/juda/www/hrc_flight/RCS/i_mcp_hv_up.html,v $ |
Version | $Revision: 1.7 $ |
Last Update | $Date: 1999/05/10 18:08:08 $ |
HRC CCB Status | Approved |
OP03 Procedures | op03: |
Delta-Time | Command Mnemonic | Description | Cmd Field Mnemonic | Data Parameter | Telemetry Verifier | Expected Value | Notes |
---|---|---|---|---|---|---|---|
00:00:01.000 | 2IMCLDS | Imaging HVPS current limit disable | 2IMCLST | DISA | sd0c00 | ||
00:00:01.000 | 2IMTBHV | Set imaging bottom MCP HV step to 53 | 2IMTBHV2 | 53 | 2IMBPAST | 53 | sd0b35 |
00:00:01.000 | 2IMTTHV | Set imaging top MCP HV step to 42 | 2IMTTHV2 | 42 | 2IMTPAST | 42 | sd0a2a |
00:00:02.000 | 2IMCLEN | Imaging HVPS current limit enable | 2IMCLST | ENAB | sd0c01 | ||
00:00:30.000 | 2IMCLDS | Imaging HVPS current limit disable | 2IMCLST | DISA | sd0c00
30 second delay for HV to settle |
||
00:00:01.000 | 2IMTBHV | Set imaging bottom MCP HV step to 61 | 2IMTBHV2 | 61 | 2IMBPAST | 61 | sd0b3d |
00:00:01.000 | 2IMTTHV | Set imaging top MCP HV step to 50 | 2IMTTHV2 | 50 | 2IMTPAST | 50 | sd0a32 |
00:00:02.000 | 2IMCLEN | Imaging HVPS current limit enable | 2IMCLST | ENAB | sd0c01 | ||
00:00:30.000 | 2IMCLDS | Imaging HVPS current limit disable | 2IMCLST | DISA | sd0c00
30 second delay for HV to settle |
||
00:00:01.000 | 2IMTBHV | Set imaging bottom MCP HV step to 68 | 2IMTBHV2 | 68 | 2IMBPAST | 68 | sd0b44 |
00:00:01.000 | 2IMTTHV | Set imaging top MCP HV step to 57 | 2IMTTHV2 | 57 | 2IMTPAST | 57 | sd0a39 |
00:00:02.000 | 2IMCLEN | Imaging HVPS current limit enable | 2IMCLST | ENAB | sd0c01 | ||
00:00:30.000 | 2IMCLDS | Imaging HVPS current limit disable | 2IMCLST | DISA | sd0c00
30 second delay for HV to settle |
||
00:00:01.000 | 2IMTBHV | Set imaging bottom MCP HV step to 76 | 2IMTBHV2 | 76 | 2IMBPAST | 76 | sd0b4c |
00:00:01.000 | 2IMTTHV | Set imaging top MCP HV step to 65 | 2IMTTHV2 | 65 | 2IMTPAST | 65 | sd0a41 |
00:00:02.000 | 2IMCLEN | Imaging HVPS current limit enable | 2IMCLST | ENAB | sd0c01 | ||
00:00:30.000 | 2IMCLDS | Imaging HVPS current limit disable | 2IMCLST | DISA | sd0c00
30 second delay for HV to settle |
||
00:00:01.000 | 2IMTBHV | Set imaging bottom MCP HV step to 83 | 2IMTBHV2 | 83 | 2IMBPAST | 83 | sd0b53 |
00:00:01.000 | 2IMTTHV | Set imaging top MCP HV step to 72 | 2IMTTHV2 | 72 | 2IMTPAST | 72 | sd0a48 |
00:00:02.000 | 2IMCLEN | Imaging HVPS current limit enable | 2IMCLST | ENAB | sd0c01 | ||
00:00:30.000 | 2IMCLDS | Imaging HVPS current limit disable | 2IMCLST | DISA | sd0c00
30 second delay for HV to settle |
||
00:00:01.000 | 2IMTBHV | Set imaging bottom MCP HV step to 89 | 2IMTBHV2 | 89 | 2IMBPAST | 89 | sd0b59 |
00:00:01.000 | 2IMTTHV | Set imaging top MCP HV step to 77 | 2IMTTHV2 | 77 | 2IMTPAST | 77 | sd0a4d |
00:00:02.000 | 2IMCLEN | Imaging HVPS current limit enable | 2IMCLST | ENAB | sd0c01 |
$Log: i_mcp_hv_up.html,v $
Revision 1.7 1999/05/10 18:08:08 jhc
corrected initial time delay to 1 sec
Revision 1.6 1998/05/18 15:47:27 juda
corrected telemetry verifier mnemonics for MCP HV Step commands (2IMTPST -> 2IMTPAST and 2IMBPST -> 2IMBPAST)
Revision 1.5 1998/05/13 18:30:48 juda
Added "File" entry to version table
Revision 1.4 1998/05/06 20:47:46 juda
Added OBC SCS #
Revision 1.3 1998/05/06 19:17:06 juda
Marked as approved
Revision 1.2 1998/05/06 19:13:36 juda
Identified this as the "autonomous" version of the sequence
Revision 1.1 1998/05/06 12:30:31 juda
Initial revision
Dr. Michael
Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356
E-mail: mjuda@cfa.harvard.edu