OP03 Procedures | op03: |
The serial digital command to the HRC to switch the synchronization signal is sent first; followed by the command to the CTU to change formats. Serial digital commands to the HRC to reset and then re-enable the serial digital telemetry FIFOs are then issued; this flushes the buffers and restarts them.
Delta-Time | Command Mnemonic | Description | Cmd Field Mnemonic | Data Parameter | Telemetry Verifier | Expected Value | Notes |
---|---|---|---|---|---|---|---|
00:00:01.000 | 2NXILASL | Select timing for HRC next-in-line mode telemetry | 2OBNLASL | NEXT | sd1a01 | ||
00:00:00.500 | CSELFMT5 | CTU telemetry mode select format 5 | CCSDSTMF | FMT5 | |||
00:00:01.000 | 2FIFOAOF | Reset event data fifo | 2FIFOAVR | RSET | sd4500 | ||
00:00:01.000 | 2FIFOAON | Enable event data FIFO | 2FIFOAVR | ENAB | sd4501 |
$Log: fmt5.html,v $
Revision 1.4 1999/05/10 18:08:08 jhc
corrected initial time delay to 1 sec
Revision 1.3 1998/09/14 20:01:54 juda
Marked as Approved - changed "Caution" of 1 major frame to synch to as many as 3 - minor grammar corrections to description section.
Revision 1.2 1998/06/08 17:53:51 juda
corrected spelling error "Rest" to "Reset"
Revision 1.1 1998/05/11 20:23:41 juda
Initial revision