OP03 Procedures op03:

HRC Command Sequences

Disable Antico Veto

Description:

This sequence sends the serial digital command to the HRC that will disable the vetoing of MCP events that are coincident with events that occur in the anticoincidence shield.

Cautions/Restrictions:

None

Flow Diagram

Delta-Time Command Mnemonic Description Cmd Field Mnemonic Data Parameter Telemetry Verifier Expected Value Notes
00:00:01.000 2SHL1ADI Disable anticoincidence shield veto     2SHLDAVR DISA sd4000


$Log: antico_veto_ds.html,v $

Revision 1.2 1999/05/10 18:08:08 jhc

corrected initial time delay to 1 sec

Revision 1.1 1999/03/03 20:04:30 juda

Initial revision

Revision 1.2 1998/09/10 14:37:24 juda

Marked as Approved - added DOCTYPE info and text alternative for flow diagram image

Revision 1.1 1998/05/19 16:32:55 juda

Initial revision