AXAF Constraints, Restrictions, & Limitations

Number: HRC-R-004

Type: Restriction

Original Date: 1998 March 18


Subsystem: HRC

Subject: Minimum dither frequency with HRC at aim-point

Source:


CRL Statement:

The frequency of the dither pattern should not be set lower than 0.36 deg/sec (0.001 Hz) when the HRC is at the aim-point of the HRMA.


CRL Rationale/Justification:

 The HRC sensitivity to bright objects is derived from the HRC design. A localized region on the HRC MCPs that receives a dose of more than 500 events per MCP channel undergoes a permanent reduction in gain of 10%; increasing dose above this leads to further reduction in gain. Dithering too slowly can allow an on-axis, imaged x-ray source to produce to high a localized dose.


CRL Impact:

The event dose from a too slowly dithered source can produce a localized permanent degradation in the HRC MCP gain.


Recommended Action:

Incorporate into the Systems and Operations Procedures, with ASC providing the inputs, and Operations Database.