Version $Revision: 1.3 $
Last Update $Date: 2001/11/08 14:46:10 $
HRC CCB Status NA

AXAF Constraints, Restrictions, & Limitations

Number: HRC-C-010

Type: Constraint

Original Date: 1998 October 13


Subsystem: HRC

Subject: HRC Electronics Power Configuration

Source: Gerry Austin


CRL Statement:

Only one side of the HRC electronics may be connected to the active spacecraft bus.


CRL Rationale/Justification:

The power configuration constraint is derived from the HRC design.


CRL Impact:

If both sides of the HRC are connected to the same power bus, the current transient experienced upon bus turn-on may result in blowing the spacecraft fuse associated with the bus resulting in the loss of power redundancy for the HRC.


Recommended Action:

Incorporate into the Systems and Operations Procedures, with ASC providing the inputs.


$Log: hrc-c-010.html,v $

Revision 1.3 2001/11/08 14:46:10 juda

HTML "href" tag edits to convert to soft links

Revision 1.2 1999/01/26 18:34:20 juda

changed text of Subject entry

Revision 1.1 1998/10/14 13:48:48 juda

Initial revision