Number: HRC-C-005
Type: Constraint
Original Date: 1/31/97
Subsystem: HRC
Subject: HRC Detector Switching
Source: Informal CARD inputs, e-mail, M. Juda, 1/28/97
CRL Statement:
HRC high voltages must be commanded OFF prior to switching from either
the Imaging detector to the Spectroscopy detector or the Spectroscopy detector
to the Imaging detector.
CRL Rationale/Justification:
The HRC sensitivity to detector switching is derived from the HRC design.
CRL Impact:
Detector switching transients will damage the HRC preamplifier inputs.
Recommended Action:
Incorporate into the Systems and Operations Procedures, with ASC providing
the inputs.