The present targets for the Total and Cold times are:
Total time per SI Mode per measurement: 7600.0 seconds
Fraction of total time the measurement should be cold: 60.0%
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Exp. Cold Time (secs) | 82080 | 82080 | 82080 |
Total Actual Cold Time (secs) | 19374 | 20677 | 27888 |
Delta From Expected (secs) | -62705 | -61402 | -54191 |
% of Exp. Cold Total (secs) | 23.60% | 25.19% | 33.98% |
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Expected Time (secs) | 136800 | 136800 | 136800 |
Total Actual Time (secs) | 114350 | 111731 | 176229 |
Delta From Expected (secs) | -22450 | -25069 | 39429 |
% of Expected Total (secs) | 83.59% | 81.67% | 128.82% |
SI Mode | Total Number of Obs. | Total Exposure Time (sec) | Average Exposure (sec/obs) |
---|---|---|---|
Primary 6 Chip SI Modes | |||
TE_007AC | 16 | 114350.00 | 7146.88 |
TE_007AE | 14 | 92297.00 | 6592.64 |
TE_00B26 | 14 | 100256.00 | 7161.14 |
Old 6 Chip SI Modes | |||
TE_00216 | 0 | 0.00 | 0.00 |
TE_0021C | 0 | 0.00 | 0.00 |
TE_008EA | 0 | 0.00 | 0.00 |
5 Chip SI Modes | |||
TE_00C60 | 5 | 46822.00 | 9364.40 |
TE_00CA8 | 2 | 19434.00 | 9717.00 |
4 Chip SI Modes | |||
TE_00C62 | 3 | 29151.00 | 9717.00 |
Totals: | 54 | 402310.00 | 7450.19 |
Rule #1: The key time period for balancing SI mode statistics is the 6 month Epoch By the end of the epoch, the SI mode statistics should match the rules stated below. Rule #2: Each of the three, default, 6 chip, SI modes (or their 5 chip equivalents) must be used at least once in each load week. - If two SI modes are lagging in either cold time or total time, apportion the week's ECS measurements between the two of them roughly commensurate with the amount they are lagging. - The 6 month Epoch allows "even" correction of two lagging SI modes. No need to pile a weeks worth of ECS measurements on one SI mode if two are lagging. Rule #3: Make certain to spread the amount of COLD ECS time as evenly as possible across all three SI modes Balance Cold measurement data between the three default 6-chip modes within 10% of each other on an Epoch basis
Rule #4: Spread the amount of *Total* ECS time as evenly as possible across all three SI modes.
- Balance Total measurement data between the three default 6-chip modes within 10% of each other on an Epoch basis.
Rule #3 takes precedence over Rule #4.
Rule #5:At least 60% of scheduled ECS measurement time must be -118.7degC
Rule #6: Any ECS measurements during a Perigee Passage that are cold MUST be assigned to the nominal ECS run SI modes. i.e. Any requested Rawmode runs can be done with a warm focal plane.
All of the TE_00CA8s get counted as TE_007AE
Half of the TE_00C60s get counted towards TE_007AC and the other half get counted with the TE_00B26s
Half of the TE_00C62s get counted towards TE_007AC and the other half get counted with the TE_00B26s.