File $Source: /home/juda/www/hrc_flight/RCS/power-down.html,v $
Version $Revision: 1.7 $
Last Update $Date: 1999/05/10 18:08:08 $
HRC CCB Status Approved

OP03 Procedures op03:

HRC Command Sequences

Power Down HRC - SCS #41

Description:

This command sequence turns off all of the HRC HVPS and then turns off the HRC low voltage. This sequence is to be used for load shedding prior to eclipse entries for which it is necessary to minimize the drain on the spacecraft batteries. This sequence should also be used when the AXAF electrical power system encounters a fault that requires the HRC load to be shed.

This sequence uses serial digital commands to shut off each of the HV power supplies, HRC-S, HRC-I, PMT 1, and PMT 2 (only one of HRC-I or HRC-S and one of PMT 1 or PMT 2 should be on). It then sends high level pulse commands to switch off both the A and B side +5V power supplies (again only one of these should be on).

This command sequence is based on the HRC EGSE scripts allhvoff.cmd and 5voff.cmd

Cautions/Restrictions:

None

Delta-Time Command Mnemonic Description Cmd Field Mnemonic Data Parameter Telemetry Verifier Expected Value Notes
00:00:01.000 2SPHVOF HRC-S HVPS Off     2SPONST OFF sd0100
00:00:01.000 2IMHVOF HRC-I HVPS Off     2IMONST OFF sd0900
00:00:01.000 2S1HVOF Shield PMT#1 HVPS off     2S1ONST OFF sd0500
00:00:01.000 2S2HVOF Shield PMT#2 HVPS off     2S2ONST OFF sd0d00
00:00:01.000 2SPTTHV Set HRC-S top MCP HV step to 0 2SPTTHV2 0 2SPTPAST 0 sd0200
00:00:01.000 2SPTBHV Set HRC-S bottom MCP HV step to 0 2SPTBHV2 0 2SPBPAST 0 sd0300
00:00:01.000 2IMTTHV Set HRC-I top MCP HV step to 0 2IMTTHV2 0 2IMTPAST 0 sd0a00
00:00:01.000 2IMTBHV Set HRC-I bottom MCP HV step to 0 2IMTBHV2 0 2IMBPAST 0 sd0b00
00:00:01.000 2S1STHV Set shield PMT#1 HV step to 0 2S1STHV2 0 2S1HVST 0 sd0600
00:00:01.000 2S2STHV Set shield PMT#2 HV step to 0 2S2STHV2 0 2S2HVST 0 sd0e00
00:00:01.000 205VAOF +5V Low Voltage Power Supply Side A Off     2PS5AON OFF hlp3f
00:00:01.000 205VBOF +5V Low Voltage Power Supply Side B Off     2PS5BON OFF hlp7f


$Log: power-down.html,v $

Revision 1.7 1999/05/10 18:08:08 jhc

corrected initial time delay to 1 sec

Revision 1.6 1998/06/03 21:55:00 juda

corrected delta-time for 205VAOF command (+5V Low Voltage Power Supply Side A Off) from 0 seconds to 1 second

Revision 1.5 1998/05/18 15:53:01 juda

corrected telemetry verifier mnemonics for MCP HV Step commands (2IMTPST -> 2IMTPAST, 2IMBPST -> 2IMBPAST, 2SPTPST -> 2SPTPAST and 2SPBPST -> 2SPBPAST)

Revision 1.4 1998/05/13 16:19:05 juda

Added "File" entry to version table

Revision 1.3 1998/05/06 18:24:18 juda

added the OBC SCS # to the sequence name field

Revision 1.2 1998/05/06 18:14:14 juda

added "to 0" to "Set shield PMT#1 HV step" - marked as approved

Revision 1.1 1998/04/29 19:25:58 juda

Initial revision


Dr. Michael Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356
E-mail: mjuda@cfa.harvard.edu